Carrier Bryant Payne HK42FZ011 1012-940 Furnace Control Circuit Board Module
Carrier Bryant Payne HK42FZ011 1012-940 Furnace Control Circuit Board Module
ICM291 ICM Furnace Control Board Module for Carrier Bryant LH33WP003 LH33WP003A







ICM291 ICM Furnace Control Board Module for Carrier Bryant LH33WP003 LH33WP003A. ICM Controls Fan Blower Control Board Part Number ICM291. This board is a replacement for the following numbers. Low cost form, fit and functional replacement for Carrier: LH33WP003A. Direct Spark Ignition (DSI) control board. Controls combustion, blower and indoor fan motors; spark ignitor; and the gas valve. Monitors timing, trial for ignition, flame sensing and lockout. 100% lockout safety feature. Compatible with LP or Natural Gas. Status LED for fault. Control Voltage: 24 VAC (18-30 VAC), 60Hz. Line Voltage: 208/230 VAC, 60Hz. Pre-Purge: 45 seconds. Trial for Ignition: 5+2 seconds. Retry Period: Every 20 seconds for 15 minutes. Lockout: Manual reset. Post-Purge: 45 seconds. Red LED: Steady ON-normal operation. Power: RT and C. Thermostat Interface: R, W, and G. Safety Switches: RS, LS, and CS. Combustion Motor Hall Effect Sensor. Spark – Gas Valve: GV. Combustion Motor: CM. Blower Motor: BM. Indoor Fan Motor: IFO. Complete with installation guide. Please see all pictures. Fan Blower Control Board. This board is a replacement for the following numbers: Carrier: LH33WP003, LH33WP003A. Control Voltage: 24 VAC (18-30 VAC), 60Hz Line Voltage: 208/230 VAC, 60Hz. Check out my other items.

X13 Furnace Blower Motor & Module 3/4 HP Fits Carrier Bryant Payne HD46MR121


X13 Furnace Blower Motor & Module 3/4 HP Fits Carrier Bryant Payne HD46MR121. This is a Brand New Drop in X13 ClimaTek Replacement Furnace Blower Motor. It is a direct replacement for the old part numbers below. It’s 3/4 HP & 115 volt. This motor requires no new wiring no field programming and no complicated installations. Simply unplug the wiring harness on your old motor and plug it into this one! The motor is 5 5/8 in diameter (Frame 48Y). It replaces the old part numbers listed below. An electric motor converts electrical energy into mechanical energy. In an HVAC system, motors typically turn the air conditioning fan blade and the furnace blower motor. Newer high efficient motors, such as X13 and ECM motors, have “end caps” that control the motor speeds. These can be removed and replaced separately. Replaces Old Part #s. Partial List of Units that Use This Item. Hit Ctrl + F and enter your model number for a quick search!

5SME39OXL036 OEM Carrier Bryant Payne 1/3 HP X13 Furnace Blower Motor & Module


BRAND NEW OEM GE Genteq Carrier/Bryant/Payne Furnace X13 Blower Motor & Module combination. The Part Number is HD42AE232. It’s 1/3 HP. The motor is 5 5/8 in diameter (Frame 48Y).

X13 Furnace Blower Motor & Module 1/2 HP Fits Carrier Bryant Payne HD44AQ258


X13 Furnace Blower Motor & Module 1/2 HP Fits Carrier Bryant Payne HD44AQ258. This is a Brand New Drop in X13 ClimaTek Replacement Furnace Blower Motor. It is a direct replacement for the old part numbers below. It’s 1/2 HP & 208-230 volt. This motor requires no new wiring no field programming and no complicated installations. Simply unplug the wiring harness on your old motor and plug it into this one! The motor is 5 5/8 in diameter (Frame 48Y). It replaces the old part numbers listed below. An electric motor converts electrical energy into mechanical energy. In an HVAC system, motors typically turn the air conditioning fan blade and the furnace blower motor. Newer high efficient motors, such as X13 and ECM motors, have “end caps” that control the motor speeds. These can be removed and replaced separately. Replaces Old Part #s. Partial List of Units that Use This Item. Hit Ctrl + F and enter your model number for a quick search!

X13 Furnace Blower Motor & Module 1/2 HP Fits Carrier Bryant Payne HD44AR234


X13 Furnace Blower Motor & Module 1/2 HP Fits Carrier Bryant Payne HD44AR234. This is a Brand New Drop in X13 ClimaTek Replacement Furnace Blower Motor. It is a direct replacement for the old part numbers below. It’s 1/2 HP & 208-230 volt. This motor requires no new wiring, no field programming, and no complicated installations. Simply unplug the wiring harness on your old motor and plug it into this one! The motor is 5 5/8 in diameter (Frame 48Y). An electric motor converts electrical energy into mechanical energy. In an HVAC system, motors typically turn the air conditioning fan blade and the furnace blower motor. Newer high efficient motors, such as X13 and ECM motors, have “end caps” that control the motor speeds. These can be removed and replaced separately. Replaces Old Part #s. Partial List of Units that Use This Item. Hit Ctrl + F and enter your model number for a quick search!

X13 Furnace Blower Motor & Module 1/2 HP Fits Carrier Bryant Payne HD42AQ234


X13 Furnace Blower Motor & Module 1/2 HP Fits Carrier Bryant Payne HD42AQ234. This is a Brand New Drop in X13 ClimaTek Replacement Furnace Blower Motor. It is a direct replacement for the old part numbers below. It’s 1/3 HP & 208-230 volt. This motor requires no new wiring no field programming and no complicated installations. Simply unplug the wiring harness on your old motor and plug it into this one! The motor is 5 5/8 in diameter (Frame 48Y). It replaces the old part numbers listed below. An electric motor converts electrical energy into mechanical energy. In an HVAC system, motors typically turn the air conditioning fan blade and the furnace blower motor. Newer high efficient motors, such as X13 and ECM motors, have “end caps” that control the motor speeds. These can be removed and replaced separately. Replaces Old Part #s. Partial List of Units that Use This Item. Hit Ctrl + F and enter your model number for a quick search!

OEM Carrier Bryant Payne Furnace 1/2 HP ECM BLOWER MOTOR Module RMOD44AE130


This is a BRAND NEW GE Genteq Carrier/Bryant/Payne ECM BLOWER MOTOR MODULE. The part # is HK44ER136 and it is 1/2 HP, 120/240 volt. Replaces the back end of an existing ECM Motor. Thanks for looking and good luck! Partial List of Carrier/Bryant/Payne Furnaces Using this Item. HD44AE133 40FKA00530051A 40FKA00531051A 40FKB00530053A FK4ANF005000AAAA49B FK4CNF005000AAAA49A FK4CNF005000AEAA46A FK4CNF005000AFAA46A FK4CNF005000AGAA59A FK4CNF005000AHAA59A FK4DNB005000AAAA64A FK4DNF005000AAAA59A FV4ANF005000AAAA45A FV4ANF005000ABAA61A FV4ANF005000ACAA61A FV4ANF005000ADAA61A FV4BNB005000AAAA45A FV4BNB005T00AAAA45A FV4BNF005000AAAA61A FV4BNF005T00AAAA61A. I could not be more pleased with my entire experience. From initial contact to the parts. I will defenitally order again. Thanks again and I will reply to this when I get the motor! We will attempt to process your address change, cancellation and order change as quickly as possible. However, we cannot guarantee that we will be able to provide this service. Please review your order for accuracy before submitting it. The time frame depends on your location and is determined by the Post Office. Tracking information is accessible once the item is delivered to the post office or picked up by UPS. For our International Buyers. These charges are not refundable for all correctly filled orders. Please review the entire listing carefully and make certain you are ordering the part you need. Please note that HVAC manufacturers frequently update their parts without warning. While we strive to update our listing pictures as quickly as possible, an outdated picture is not grounds for return. You must obtain a return authorization to return the part within this time frame. Parts are not eligible for return for any reason if we are not notified within the 14 day time frame. This is to insure that we can file a claim with the carrier when applicable. All items must be in a brand new (without signs of installation) and resaleable condition. All parts are inspected for signs of installation upon our receipt of them. The decision is made based on our assessment of the part and whether it can be resold as “used”. In no way shall North America HVAC be liable for any loss, damage, fire, explosion, injury, including any incidental or consequential damages, or death as a result of ordering and/or installing any parts from our website or from the results of any action taken due to reading information found on our website. The information is provided as a courtesy to our customers to enhance their understanding of their HVAC system, it is not to be taken for instructional purposes on how to repair their system. North America HVAC suggests having all parts, accessories and equipment installed by a qualified heating and air conditioning technician. If a customer attempts to install a part, accessory or equipment, he or she should have a thorough understanding of electricity, reading wiring diagrams and the work to be performed. In no way shall North America HVAC be liable for any loss, damage, injury, including any incidental or consequential damages, or death as a result of ordering and/or installing any parts from our website or from the results of any action due to reading information found on our website. The free listing tool.

X13 Furnace Blower Motor & Module 1/2 HP Fits Carrier Bryant Payne HD44AR233


X13 Furnace Blower Motor & Module 1/2 HP Fits Carrier Bryant Payne HD44AR233. This is a Brand New Drop in X13 ClimaTek Replacement Furnace Blower Motor. It is a direct replacement for the old part numbers below. It’s 1/3 HP & 208-230 volt. This motor requires no new wiring, no field programming, and no complicated installations. Simply unplug the wiring harness on your old motor and plug it into this one! The motor is 5 5/8 in diameter (Frame 48Y). An electric motor converts electrical energy into mechanical energy. In an HVAC system, motors typically turn the air conditioning fan blade and the furnace blower motor. Newer high efficient motors, such as X13 and ECM motors, have “end caps” that control the motor speeds. These can be removed and replaced separately. Replaces Old Part #s. Partial List of Units that Use This Item. Hit Ctrl + F and enter your model number for a quick search!
