Carrier SD01 81104165 ECM Draft Inducer Motor & Controller HR46GH003? Checked



Carrier ECM Motor Draft Inducer Assembly with Motor, Wiring Harness, Machine screws mounting posts and motor shaft set screw as shown in the photos. 120 VAC 50/60 Hz 1.64 A. Carrier Part No: HR46GH003. FASCO 71500178 / 71500178J. Wiring harness as shown. Machine screws, mounting posts, set screw, motor mounting screw screws as shown. This is an OEM Carrier ECM Draft Inducer ECM Controller and Motor for a Cartier Infinity series and Bryant Evolution series high efficiency Furnace. This was checked in and removed from a working carrier high-efficiency furnace with an ECM checker, by two Carrier HVAC professionals. It includes everything you see in the photos. This ECM Motor is programmed to work with specific furnaces. All part numbers and specs must match exactly or this is not the correct part. If you’re not sure this is the correct part, or you’re not sure you need a draft inducer motor, please write BEFORE purchasing and I will be glad to help. If this is what you need, I believe it’s an excellent value. But please understand this is not a part you can try – to see if it’s what you need, and return if you discover it wasn’t what you needed. While this is a relatively simple part to install, it is not simple to diagnose. If you do not have these skills, it is significantly more likely you could have issues. Please write if you have any questions and I will be glad to help. I will also be glad to provide step-by-step instructions on how to remove your ECM draft inducer assembly from your furnace, and how to replace this ECM module and motor in your assembly. I have included all machine screws mounting posts etc. Needed for this job so you’ll have a spare for each one. Ive included detailed photos of this motor from multiple angles. It was checked in and removed from a working furnace by two HVAC professional with an ECM Checker. Please understand the company I work for is kind to allow me to sell parts, I enjoy working for them and I will not sell within their service area so there’s no chance I could possibly be competing against them. WHAT YOU CAN EXPECT FROM ME. IF YOU HAVE AN ISSUE. Thank you for your interest! This is not a business or parts dealer. I work for an HVAC company and the majority of the parts I sell here are used, from equipment I’ve removed. And if you do have a question, I actually work in heating and air conditioning and it’s likely I can answer it. If you’re replacing parts trying to figure out what’s wrong with your equipment, if you’re not sure this is what you need you might want to return it, I’m probably not your best choice. I do my best to make this possible, including. All used parts I sell have been checked to confirm they work properly. Important part numbers and model numbers are included in the listing title, the item, specifics, and the description. Clear photos of the part from multiple angles are included. All parts are packed securely. (Control boards are wrapped in static guard). Buyers are responsible purchasing the correct part for their application. Please check part numbers, review specs and photos to confirm this is the correct part! If you’re not sure this is what you need, please ask! Buyers are responsible for properly installing this part, and for having the knowledge, experience and proper tools needed to correctly install this and check to confirm it is installed correctly and safely. Buyers are responsible for correctly diagnosing their need for this part. You have seven days from the date you receive it to check it and report any issues. GUARANTEE TO ALL OTHERS. To all others, please understand you are purchasing this at your risk and not mine. I do guarantee you will receive the part shown in the photos. WHY IS MY GUARANTEE DIFFERENT FOR HVAC PROFESSIONALS VERSUS OTHERS? Manufacturers and suppliers of HVAC equipment and parts recommend installation and servicing only by licensed HVAC professionals. Many if not most suppliers of HVAC equipment and parts will only sell to licensed HVAC contractors. Licensed HVAC Professionals typically must successfully complete a significant amount of training and hands on experience as an apprentice, and pass tests to prove their competence. While professionals can also make mistakes, it is MUCH more likely someone trying to fix their own equipment will have an issue. While it is possible for someone who is not an HVAC Professional to fix their own equipment- it is significantly more likely they will have issues than a licensed, HVAC professional. I do my best to ensure this. As many detailed photos.. Or as much information as I do. If you are not sure this is what you need, please write before purchasing and I will gladly check to confirm this is the correct replacement part or provide guidance and answer questions about how to check to determine if this is even what you need. If after purchasing, you determine this was not what you needed, please don’t give up! I still I still do care that you are pleased and I will do my best to help you. If you take the time to write, you can count on me to respond and do my best to help. I have helped many people figure out and resolve the issues with their HVAC equipment – you can see their comments in my feedback. Please write if you have any questions.
ClimaTek X13 Furnace Blower Motor Fits Carrier Bryant Payne HD44MQ133 HD44MQ134
ClimaTek X13 Furnace Blower Motor 1/2 HP Replaces Carrier Bryant Payne HD44MQ133 HD44MQ134. This is a new ClimaTek X13 Furnace Blower Motor 1/2 HP. It replaces the part numbers listed below. An electric motor converts electrical energy into mechanical energy. In an HVAC system, motors typically turn the air conditioning fan blade and the furnace blower motor. Newer high efficient motors, such as X13 and ECM motors, have end caps that control the motor speeds. These can be removed and replaced separately. Replaces Old Part #s. Partial List of Units that Use This Item. Hit Ctrl + F and enter your model number for a quick search!

ClimaTek Draft Inducer Blower Replaces Carrier Bryant Payne A. O. Smith JE1D014N

ClimaTek Draft Inducer Blower Replaces Carrier Bryant Payne A. This is a new ClimaTek Draft Inducer Blower It replaces the part numbers listed below. An inducer motor is designed to expel the exhaust gas from the furnace. Older inefficient furnaces allowed the flue gas to escape the unit with virtually no resistance. Newer high efficient furnace heat exchangers are so restrictive that the flue gases cannot exit the furnace though natural draft. Therefore, the inducer is required to pull the flue gases through the heat exchanger. The inducer motor is usually the first thing that starts up when your furnace calls for heat. Replaces Old Part #s. Partial List of Units that Use This Item. Hit Ctrl + F and enter your model number for a quick search!
Furnace Draft Inducer Blower Motor Kit for Carrier/Bryant 58PAV, 115V

Vehicle Fitment? The HC21ZE117B blower motor kit compatible with Carrier, Bryant, Payne, Jakel furnace blower motor. Inducer motor replaces model numbers: HC21ZE114, HC21ZE114A. Safety Protection? The 318984-75 blower motor kit is designed for efficient removal of furnace exhaust gases, ensuring stable operation of the combustion system. The motor activates before ignition to clear residual combustible gases from the combustion chamber and continuously expels exhaust during operation. Built-in 120? Thermal protector automatically cuts off the circuit to prevent coil burnout when temperature exceeds 120? Due to prolonged operation, abnormal voltage, or poor ventilation. It withstands prolonged exposure to furnace heat, ensuring safe operation and a long service life. Motor Volts: 115V, Amperage: 1.5A, Frequency: 60Hz, 25MHP, Speed: 3200RPM. INS CLASS B, Rotation: Clockwise, Duty Thermally Protected. Quiet Operation? The HC21ZE114 motor kit features a quiet design for smooth and silent performance. It minimizes turbulence and vortex noise during airflow, delivering strong exhaust efficiency while maintaining lower wind noise levels. Easy Installation? This is a direct replacement part, equipped with two wire book adapters, requiring no modifications to your furnace.
Carrier Bryant CEPL130904-02-R Furnace Terminal Control Circuit Board HK50AA051
5KCP39PGV623CS Blower Fan Motor Replaces Carrier Bryant Payne HC45TE113
LEUNGOO 3/4 HP Furnace Blower Motor – 115V, 1075 RPM, 3-Speed, Replaces Carrier HC45TE113. Restore reliable airflow in your heating and cooling system with the LEUNGOO 3/4 HP Furnace Blower Motor. Designed as a replacement for compatible Carrier, Bryant, and Payne furnace blower motors, this unit combines three-speed operation, reversible rotation, and a durable metal construction. It is a practical solution for replacing a worn or failed furnace blower motor. ? Residential furnace and HVAC system repairs. ? Replacing compatible Carrier, Bryant, and Payne blower motors. ?? Restoring proper airflow in heating and cooling systems. ?? HVAC technicians and home maintenance projects. 3/4 HP Motor: Provides dependable power for compatible furnace blower applications. ? Three-Speed Operation: Offers three selectable operating speeds for flexible airflow control. ? 1075 RPM Performance: Designed for consistent blower operation. ? Reversible Rotation: Supports clockwise or counterclockwise rotation when properly configured. ?? Durable Construction: Features a metal motor housing and ball-bearing design. ? 48Y Frame: Approximately 5-5/8″ motor body diameter with a 1/2″ shaft. ? Replacement Compatibility: Replaces compatible GE Genteq 5KCP39PGV623CS, Carrier HC45TE113, and Packard 82113 models. ? Capacitor Included: Supplied with a 15 MFD / 370V capacitor. ? Why Buyers Choose It. The LEUNGOO blower motor offers a practical replacement option for several commonly used furnace motor models. Its three-speed operation, reversible rotation, and included capacitor help simplify compatible HVAC repair projects while providing the specifications needed for everyday furnace blower applications. 1 × LEUNGOO 3/4 HP Furnace Blower Motor. 1 × 15 MFD / 370V Capacitor. ? Practical HVAC Replacement Upgrade. Get your compatible furnace blower system back in operation with a replacement motor designed for dependable airflow and flexible installation. The LEUNGOO motor is a useful option for HVAC maintenance, furnace repairs, and replacing an existing compatible blower motor. Important: Verify your original motor’s model number, voltage, horsepower, RPM, speed settings, mounting configuration, shaft dimensions, and rotation requirements before purchasing. Designed for compatible Carrier, Bryant, and Payne furnace applications. Professional installation by a qualified HVAC technician is recommended. Disconnect electrical power before installation.
Upgrade Furnace Control Board for Carrier Bryant Performance Guaranteed 1
Upgrade Furnace Control Board for Carrier Bryant – Performance Guaranteed 1. Upgrade Furnace Control Board for Carrier Bryant. Performance Guaranteed for 1! Compatible Part Numbers: , CEPL130590-01, CEBD430590-10A, 1172550, 359AAV036060AAAA, 58HDX060 10112, 58HDX080 10112, including models using the control board. OEM Performance: Designed to replace Carrier, Bryant, and Payne furnace circuit boards, ensuring seamless compatibility with existing systems. Enhance Heating Efficiency: Built for reliability with high-temperature rated components. Each board undergoes extensive testing, including a 48-hour burn-in under extreme conditions. Easy Installation: Features identical plug connectors and mounting points, enabling a direct replacement without any modifications. 1- : Enjoy peace of mind with our worry-free ; replacement at zero cost if any failures occur within the period. Restores heating efficiency and ensures long-term stability in your HVAC system. Engineered for seamless integration ensures you won’t face compatibility issues. Quick setup with no drilling needed, allowing you to get back to comfort in no time. 100% machine-tested for quality assurance, providing you the confidence your furnace will operate flawlessly. Why You Should Choose This Upgrade Furnace Control Board. Elevate your heating system’s performance with our Upgrade Furnace Control Board, meticulously crafted for compatibility and quality. Each board undergoes rigorous testing to ensure peak performance, providing you with a reliable solution that not only meets but exceeds OEM standards. The design allows for a smooth installation, restoring warmth and efficiency in your home promptly. Your satisfaction is our priority, and we invite you to experience the blend of quality and dependable performance. Make the smart upgrade today! Alternative Carriers – We may use alternative carriers e. To ensure your package arrives safely and on time. Your feedback is extremely important to us. We strive to provide the best products and customer service possible. We are committed to resolving any problems and ensuring your satisfaction. Model: Furnace Control Board. Unit Quantity: 0.75 lb. Compatible Brand: Furnace Control Board. Compatible Product: Air Conditioner Split System, Central Air Conditioner, Central Furnace, Packaged/Rooftop Air Conditioner Unit. Power Source: Not Electric. Item Length: Furnace Control Board. Item Weight: 0.75 lb. Item Width: Furnace Control Board. Item Thickness: Not Specified. Type: Furnace Control Board. Power Phase: 1 Phase.

Carrier Hvac HK42FZ061- Genuine OEM Replacement Part


The Carrier Hvac HK42FZ061 is a genuine OEM replacement part designed for use in HVAC systems. Manufactured by Carrier Hvac in the United States, this part is specifically designed for food service applications, ensuring quality and compatibility with the specified model. With a focus on reliability and performance, this replacement part is essential for maintaining and repairing HVAC systems in commercial settings.
X13 Furnace Blower Motor & Module 1/2 HP Fits Carrier Bryant Payne HK44ER233
X13 Furnace Blower Motor & Module 1/2 HP Fits Carrier Bryant Payne HK44ER233. This is a Brand New Drop in X13 ClimaTek Replacement Furnace Blower Motor. It is a direct replacement for the old part numbers below. It’s 1/2 HP & 208-230 volt. This motor requires no new wiring no field programming and no complicated installations. Simply unplug the wiring harness on your old motor and plug it into this one! The motor is 5 5/8 in diameter (Frame 48Y). It replaces the old part numbers listed below. An electric motor converts electrical energy into mechanical energy. In an HVAC system, motors typically turn the air conditioning fan blade and the furnace blower motor. Newer high efficient motors, such as X13 and ECM motors, have “end caps” that control the motor speeds. These can be removed and replaced separately. Replaces Old Part #s. Partial List of Units that Use This Item. Hit Ctrl + F and enter your model number for a quick search!
OEM Carrier Bryant HR46GH001 ECM Draft Inducer Assembly
This part was removed by a certified hvac installer from a fully functioning system. The part has been inspected and was in working condition when removed.











